Details

Complete cardiovascular imaging system produces high-quality images for challenging fluoroscopy procedures

The Philips Allura Xper FD10 is a complete cardiovascular imaging system designed for a variety of interventional cardiology procedures. The Philips Allura Xper FD10 produces high-contrast images with low noise, making it an ideal system for challenging cardiac fluoroscopy, vascular fluoroscopy, and trace subtract fluoroscopy procedures.

For more information on the Philips Allura Xper FD10 Cath Lab/Angio System, available refurbished through Avante Health Solutions, contact a representative today.

Features

  • Floor-mounted Poly Diagnost G stand
  • High output MRC X-Ray tube
  • Counter-balanced Flat Detector
  • Xper Table
  • Flexible monitor ceiling suspension with height adjustment
  • Optional examination light
  • Xper data and review LCD monitors
  • Xper Module
  • Xper Review Module
  • Xper Geometry Module
  • Optional: Xper geometry and imaging modules — ask your Avante representative for more information.

Features

  • Complete cath lab system provides exceptional image quality for coronary angiography.
  • Flat panel detector increases image contrast while reducing noise.
  • Ideal for challenging cardiac fluoroscopy, vascular fluoroscopy, and trace subtract fluoroscopy procedures.
  • Proprietary Xper (x-ray personalized) feature lets each clinician customize the system for their unique workflow, allowing for confident and fast diagnoses.
  • Philips Allura 3D-RA analysis package generates high-resolution 3D images from a single rotation angiography run in only a few seconds.
  • 3D-RA also offers enhanced visualization of the anatomical vessel structure.
  • Fluid workflow and DICOM integration brings together advanced image acquisition and visualization tools, multi-modality access, hemodynamic monitoring, and integrated reporting.
  • StentBoost technology enhances stent visualization.
  • G-shaped, floor-mounted, motorized gantry is compact and provides excellent patient stability from all sides.
  • While the G-arm is compact, the unit’s design can accommodate virtually all cardiac projections, even with obese patients.
  • Xper cardiovascular table features a free-floating table top and a 550-pound weight capacity.
  • Table tilting function with automatic safeguarding system with manual override.
  • Table pivot option designed for angiographic and interventional procedures of the upper peripherals.
  • Convenient ceiling suspension enables you to freely rotate and adjust the monitors (available with two, four, or six monitors).

Specifications

Gantry

  • Suitable for minimum ceiling heights of 240 cm (94.5 in)
  • Depth of G-arm: 105 cm (41.3 in)
  • Ultra-flexible projection angles: angulation from 45° cranial to 45° caudal, rotation from 120° LAO to 120° RAO
  • Motorized rotation speed: maximum speed up to 25°/second
  • Motorized angulation speed: maximum speed up to 18°/second with variable speed, configurable via Xper settings
  • Storage and recall of two scratch positions
  • Isocenter to floor distance: 106.5 cm (41.9 in)
  • Focal spot to isocenter distance: 76.5 cm (30.1 in)
  • Focal spot to flat detector distance: 86.5 to 123 cm (34.1 to 48.4 in). The detector can be positioned manually or via motorized movement
  • The gantry can be rotated for parking to provide system-free patient accessibility: can be moved motorized at a speed of 12°/second, automatic snap positions at -90°, 0°, and 90°
  • The system is delivered standard with two black and white 18-inch LCD monitors in the examination room
  • One 19-inch LCD color monitor and one 18-inch black and white LCD monitor are standard in the control room

Xper Table

  • Radio translucent carbon fiber tabletop
  • Tabletop length: 319 cm (125.5 in)
  • Tabletop width: 50 cm (19.6 in)
  • Motorized height movement: 79 - 107 cm (31 - 42 in)
  • Tabletop metal free overhang: 125 cm (49 in)
  • Free float at 0 degrees tilt
  • Longitudinal float: 120 cm (47 in)
  • Transversal float: 36 cm (14 in)
  • Maximum allowable patient weight: 250 kg (550 lb) with additional force of 500 N (100 kg / 220 lb) allowed in case of CPR. CPR can be performed while the tabletop is set in any longitudinal position
  • Comfortable patient mattress
  • The Xper Module, Xper Imaging, and Xper Geometry Modules can be positioned on three sides of the patient support
  • Cables incorporated in the table to allow maximum operational flexibility
  • Table position coordinates
  • Maximum tilt range: -17° (head-down) to +17° (head-up)
  • Tilt speed: 2 degrees/second
  • Isocentric cradle
  • Maximum cradle range: -15° to +15° for the full tilt range
  • Cradle speed: 3 degrees/second
  • Pivot range moves from -90° to +180° (or -180° to +90°) with locked positions at 0°, -13°, and +31° (to facilitate arm angiography) and -90°, +90°, and 180°

Monitor Ceiling Suspension

  • Monitors rotate freely on the high ceiling suspension over a range of 350°
  • Suspension moves transversely over a distance of 300 cm (118.1 in) and longitudinally over a distance of 330 cm (129.9 in)
  • Allows motorized height adjustment over a maximum range of 32 cm

Flat Panel Detector

  • Size of detector housing, including BodyGuard: 37 cm (14 in) diagonal
  • Field of view: 25 cm (10 in), diagonal square
  • Detector zoom fields: 19 and 15 cm (8 and 6 in) diagonal square format
  • Pixel size: 184 x 184 microns to allow visualization of the smallest details
  • Detective Quantum Efficiency DQE (0): 75%
  • Output digital video frame: 1024² at 14-bit depth resolution
  • Acquisition speeds can not be customized per system: 3.75, 7.5, 15 and 30 frames/second
  • Digital video frame out of archiving purposes is customizable via Xper settings in different formats: 1024², 512², 8 or 10 bit

Velara X-ray Generator

  • Microprocessor-controlled, 100 kW high-frequency converter generator
  • Quartz-controlled IGBT power switch, with a minimum switching time of 1 ms
  • Voltage range: 40 to 125 kV
  • Maximum current: 1250 mA at 80 kV
  • Maximum continuous power: 2.5 kW for 0.5 hours, 2 kW for 0.8 hours
  • Nominal power (highest electrical power): 100 kW (1000 mA at 100 kV)

MRC-GS 0508 X-ray Tube

  • 0.5/0.8 nominal focal spot values with maximum loadability of 45 kW and 85 kW
  • Grid switching with pulsed fluoroscopy
  • Anode heat dissipation in continuous mode: 3200 W
  • Fluoro power for 10 minutes: 4500 W
  • Fluoro power for 20 minutes: 3500 W
  • Maximum heat dissipation of assembly: 3500 W
  • SpectraBeam dose management
  • Oil-cooled X-ray tube with thermal safety switch

Color LCD Monitor

  • 19-inch color LCD display
  • Native format: 1280 x 1024 SXGA
  • Wide viewing angle: approximately 170°
  • Controlled brightness: typically 270 Cd/ m², with ambient light dependent brightness control
  • On-screen display of control functions operated via push buttons
  • Audio output 0.5 watt
  • Contrast typically 800 on 1

Monochrome LCD Monitor

  • 18-inch monochrome LCD display with a native format of 1280 x 1024 SXGA
  • 10 bit gray-scale resolution with gray-scale correction
  • Wide viewing angle: approximately 160°
  • High brightness: maximum 600 Cd/m², with ambient light dependent brightness control
  • On-screen display of control functions operated via push buttons
  • Examination room LCD monitors include protection screen and motorized height adjustment